fetal doppler heart rate monitor
Live Support
Fetal doppler Live Help
Fetal Dopplers  Categories
Home Fetal Doppler Home Fetal Doppler
Hospital Fetal Monitor Hospital Fetal Monitor
Fetal Dopplers  Latest
Hospital Fetal Monitor RFM300B Hospital Fetal Monitor RFM300B - $1,125.00 ($1,125.00 incl. TAX)
hospital fetal monitor RFM300A Hospital Fetal Monitor RFM300A - $1,149.00 ($1,149.00 incl. TAX)

Hospital Maternal Fetal Monitor RFM900A

Printer Friendly Tell a Friend
hospital maternal fetal monitor RFM900A
Price: $1,649.00 ($1,649.00 incl. TAX)

Qty:

Highlights:
  • 72 hours graphic trends and tabular of all parameters 
  • 12.1 inch super resolution color TFT display
  • Uterine contraction and fetal movement marker
  • Continuous real time recording of fetal heart rate 
  • Can be switched to normal patient monitoring interface

  •   Description  
    Features:            

    • 12.1 inch super resolution color TFT display
    • Maximum 9 waveforms
    • Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate
    • Combined functions of maternal monitor and fetal monitor
    • Measure the intrapartum patient and fetal heart rate
    • Uterine contraction and fetal movement marker
    • Continuous real time recording of fetal heart rate
    • Can be switched to normal patient monitoring interface
    • 72 hours graphic trends and tabular of all parameters
    • 1440 groups of NIBP data storage
    • ST analysis
    • Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care
    • Use wide-angle, multi-wafer, wide beam and ultrasonic probes

    Standard configuration:            

    • FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery, thermal printer

    Optional:            

    • Dual TEMP

     

    Technical Specifications:

    Safety

    IEC60601 approved (GB9706)

    Power source

    AC100V-240V, 50/60Hz

    Size

    330mm(L) × 275mm(W) × 160mm(H)

    Net weight

    5.0 kg

    Working

    Temperature: 5 ~ 40
    Humidity <= 85%

    Transportation and Storage

    Temperature: -20 ~ 55
    Humidity <= 85%

    Ultrasonic Probe: (Fetal Heart Rate)

    Type

    Type B proof, dirctional, using pulse doppler system

    Working frequency

    2.5 MHz

    Transmitting power density

    1.2m W/cm2

    Probe

    Multi-wafer probe

    Sample rate

    5 ms

    Calculating precision of FHR

    0.25 bpm

    Accuracy of FHR

    1 bpm (100-180 bpm)

    Marker (Fetal Movement)

    Manually push button mode

    When pressed, a red strip will be displayed above the FHR graph

    Uterine Contraction Pressure

    Type B proof

    Uterine contraction pressure probe

    Manual zero adjustment

    Design pressure sensitivity: 0-100%

    ECG

    Lead

    5 leads (R, L, F, N, C)

    Lead selection

    I, II, III, avR, avL, avF, V

    Waveform

    7 channels

    Gain selection

    ×0. 5, ×1, ×2

    HR and alarm range

    Adult: 15-300bpm
    Neonate/pediatrics: 15-350bpm

    Accuracy

    ±2% or ±2bpm, whichever is greater

    Input impedance

    > 5ΜΩ

    Voltage range of electrode polarization

    ±300mV

    Leakage current

    < 30uA

    Filter

    Diagnostic mode: 0.05 ~ 100Hz
    Monitoring mode: 0.5 ~ 35Hz
    Surgical mode: 1 ~ 25Hz

    Scaling signal

    1mV ± 3%

    Measurement range

    -1.0mV ~ +1.0mV

    Alarm Range

    -0.80mV~0.80mV

     RESP

    Model

    RA-LL impedance

    Measurement range

    Adult: 0 ~ 120bpm
    Neonate/pediatrics: 1 ~ 150bpm

    Resolution

    1rpm

    Accuracy

    ±2rpm

    NIBP

    Method

    Automatic oscillometric

    Operation mode

    Auto/Manual

    Alarm Type

    Systolic, Diastolic, Mean

    Measurement ranges

    Systolic BP: 40 ~ 300mmHg
    Diastolic BP: 10 ~ 220mmHg
    Mean BP: 20 ~ 240mmHg

    Resolution

    1mmHg

    Accuracy

    Max average error ±5mmHg or ±5%, whichever is greater

    Overload Protection

    Double safety protection

     SPO2

    Measurement Range

    0 ~ 100%

    Alarm range

    0 ~ 100%

    Resolution

    1%

    Accuracy

    ±2% (80~100%)
    ±3% (60~79%)

     PULSE RATE

    Range

    0 ~ 254bpm

    Resolution

    1bpm

    Accuracy

    ±1bpm or ±2%, whichever is greater

    Alarm delay time

    10sec

     TEMP

    Channel

    2 channels

    Measurement range

    0~50

    Alarm range

    0~45

    Resolution

    0.1

    Accuracy

    ±0.2